Komatsu — E-32 Travel alarm does not sound

TESTING AND ADJUSTING E-32 E-32 Travel alarm does not sound PC210/240-7K 20-545 Failure information • The travel alarm does not sound while the machine is traveling. • The alarm begins to sound when the machine is at a standstill. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Fuse No. 15 fault When the fuse is blown, there is a big possibility that grounding fault occurred in the circuit. 2 Travel signal fault If the monitor display is not correct, proceed to No. E-21 Troubleshooting. Monitoring code Item Normal display 019 Travel Control lever operation: ON Control lever NEUTRAL:

OFF 3 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between FB1-15 outlet to J03 and A43 (female) Resistance value Below 1 Ω Wiring harness between A43 (female) and J01 Resistance value Below 1 Ω 4 Grounding fault of wiring harness (Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between FB1-15 outlet to J03 and A43 (female) and grounding Resistance value Above 1 MΩ 5 Travel alarm fault As this is an internal failure, troubleshooting cannot be conducted. (If none of the causes listed in Item 1 through 4 above is found, the travel alarm is judged as defective)