Lubrication system Cleaning the centrifugal oil cleaner Designation Illustration Torque wrench 2-20 Nm with exchangeable ratchet head 340 130 When cleaning the centrifugal oil cleaner there will be some dirt deposits in the rotor cover. If this is the case, this indicates that the rotor is working. If it is clean and not working, the cause must be established immediately. If the dirt deposit exceeds 28 mm at the recom- mended intervals, the rotor cover should be cleaned more often. WARNING! x 1.5 The oil may be hot. Carefully remove the cover from the centrifugal oil cleaner. 1. Clean the cover. Unscrew the nut securing the outer cover. 2. Let the oil run out from the rotor. 3.
Lift out the rotor. Wipe off the outside. Undo the rotor nut and unscrew it about 1.5 turns to protect the bearing. 133 315 Note: Take care not to damage the rotor shaft. OPM 300 en-GB 39 © Scania CV AB 2015, Sweden