Yanmar — Checking the Battery Electrolyte Level (Serviceable Batteries Only)

PERIODIC MAINTENANCE 5. Be sure to bleed air from the fuel system. See Bleeding the Fuel System on page 30 . NOTICE Never attempt to remove the covers or fill a maintenance-free battery. Checking the Battery Electrolyte Level (Serviceable Batteries Only) Never operate with insufficient battery electrolyte. Operating with insufficient electrolyte will destroy the battery. 4. If the electrolyte level is lower than the minimum fill level (Figure 7, (1)) , fill with distilled water (Figure 7, (2)) (available locally) up to the upper limit (Figure 7, (3)) of the battery. WARNING Figure 6 Exposure Hazard. Batteries contain sulfuric acid.

Never allow battery fluid to come in contact with clothing, skin or eyes. Severe burns could result. Always wear safety goggles and protective clothing when servicing the battery. If battery fluid contacts the eyes and / or skin, immediately flush the affected area with a large amount of clean water and obtain prompt medical treatment. 2 UPPER LEVEL LOWER LEVEL 3 1 NOTICE Never turn off the battery switch (if equipped) or short the battery cables during operation. Damage to the electrical system will result. Figure 7 0004566 1 – Lower Level 2 – Distilled Water 3 – Upper Level Battery fluid tends to evaporate in high temperatures, especially in summer.

In such conditions, inspect the battery earlier than specified. Note: The maximum fill level is approximately 10 to 15 mm (3/8 to 9/16 in.) above the plates. 1. Make sure the engine is off. 2. Turn the battery switch to OFF (if equipped) or disconnect the negative (-) battery cable. 3. Remove the plugs and check the electrolyte level in all cells. 66 YM Series Operation Manual