Toyota — Toyota Equipment Manual (EN)

2-68 REASSEMBLY Control panel reassembly drawing Traveling/Material Handling Controller (15 ~ 32 Model (Chopper-less)) T = N m (kgf-cm) [ft-lbf] T = 15 ± 2 (150 ± 20) T = [10.2 ± 1.4] T = 9.8 ± 2 (100 ± 20) [7.2 ± 1.4] T = 9.8 ± 2 (100 ± 20) T = [7.2 ± 1.4] T = 15 ± 2 (150 ± 20) T = [10.2 ± 1.4] T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] T = 2.5 ± 0.5 (25 ± 5) T = [1.8 ± 0.4] CN119 T = 0.7 ± 0.1 (7 ± 1) T = [0.5 ± 0.07] CN116 T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] T = 15 ± 2 T = (150 ± 20) T = [10.2 ± 1.4] T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] CN131 CN133 CN135 T = 0.7 ± 0.1 (7 ± 1) T = [0.5 ± 0.07] CN132 CN137 CN126 CN114 CN118 CN127 CN130 T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] CN115 T = 1.5 ± 0.2 (15 ± 2) T = [1.1 ± 0.14] CN117 T = 1.5 ± 0.2 (15 ± 2) T = [1.1 ± 0.14] T = 9.8 ± 2 (100 ± 20) T = [7.2 ± 1.4] CN131 CN133 T = 15 ± 2 T = (150 ± 20) T = [10.2 ± 1.4] CN139 T = 15 ± 2 (150 ± 20) T = [10.2 ± 1.4] CN130 CN117 CN132 2.0 ~ 3.2 model Caution:

Be sure to install insulating sheets without fail. Failure to install the insulating sheet for the TMD will damage the TMD. Check the insulation resistance between the bracket and each P terminal after controller reassembly. Standard: 3 M Ω or more