2-85 LS L (for lift) MATERIAL HANDLING LEVER SWITCH ADJUSTMENT 1. Operate the lift lever or the 3rd lever and check continuity of the limit switch. Standard: For lift: Between CN11-1 and CN11-2 Not operated: OFF ( ) Operated: ON (0 Ω ) CN11 LS ATT (for 3rd) Standard: For 3rd: Between CN11-2 and CN11-3 Not operated: OFF ( ) Operated: ON (0 Ω ) 2. Operate the lift lever or the 3rd lever and check that the limit switch is turned on at dimension A beyond the no- play position. A = 10 ~ 20 mm (0.40 ~ 0.79 in) Lever looseness A A 3. If the limit switch ON timing is deviated from dimension A, adjust the limit switch position. LS L NO.2 For Chopper 1.
Operate the lift lever and check continuity of the limit switch No.2. Standard: Lift: Between CN39-1 and CN39-2 Not operated: ON ( ) Operated: OFF (0 Ω ) CN39 2. Pull the lift lever and check if limit switch No. 2 turns off within dimension A from the lever end. Lever neutral A = 10 ~ 20 mm (0.40 ~ 0.79 in) A Lever end 3. If the OFF timing of limit switch No. 2 is not within dimension A, adjust by turning the adjusting bolt. As for the tilt lever, the micro-switch is built in the control valve ASSY. So, no adjustment is required. LS L NO.2 Adjusting bolt