Toyota — Toyota Equipment Manual (EN)

3-40 I/O MONITOR2 This function displays the ON/OFF status of traveling and swing switches and analog input voltages of sensors. Operation Procedure 1. Display the ANALYZER MENU screen. 2. Press switch (2) twice. 3. Check that the 3. I/O MONITOR2 is displayed and press switch (3) to enter the I/O MONITOR2 function and to sequentially display I/O2-1 to I/O2-7 menu. 4. Functions of switches on this screen are as follows: Switch (1): Unused Switch (2): Unused Switch (3): Press switch (3) each time to sequentially change the screen from I/O2-1 to I/O2-7. Note: Press switch (3) on the I/O2-7 menu to return to the ANALYZER MENU screen.

It is impossible to directly jump from I/O MONITOR2 function screen to another test menu. Return to the ANALYZER MENU screen once and then go to the desired test screen. Switch (1) Switch (2) (1) I/O2-1 menu POTA:Accelerator potentiometer voltage (V) a Standard voltage when the accelerator pedal is not depressed (SWAC at OFF): 0.3 to 2.4 V b Standard voltage when the accelerator pedal is depressed to its stroke end: 1.7 to 4.7 V c Normal if b - a = 1.4 V or more Press switch (3) Switch (3) Switch (4) SWAC:Accelerator switch check When accelerator pedal is not operated: 0 OFF When accelerator pedal is depressed:

1 ON Switch ON/OFF quality judgment by operating the accelerator pedal Press switch (3) (2) I/O2-2 menu Direction switch check DSF: Forward switch, DSR: reverse switch Press switch (3) 15 18 model (dead-man brake spec. only) 1 ON 0 OFF Switch ON/OFF quality judgment by operating the direction lever 1 ON 0 OFF Indication Operation DSF DSR Forward traveling 1 0 Neutral 0 0 Reverse traveling 0 1 Indicati Operation on DSF DSR Forward traveling 0 1 Neutral 0 0 Reverse traveling 1 0