Toyota — Toyota Equipment Manual (EN)

4-3 Short circuit check 1. Disconnect the connectors at both ends of the corresponding harness. 2. Measure the resistance between the corresponding connector terminal and N1. Always inspect the connectors at both ends. Standard: 1 M Ω or more. Note: Measure while lightly shaking the wire harness up and down and sideways. 4 3. Measure the resistance between a terminal corresponding to the connector terminal and N1. Be sure to inspect the connectors at both ends. Standard: 1 M Ω or more. Note: The wiring may short-circuit due to pinching by the body or defective clamping. Visual and contact pressure checks Disconnect the connectors at both ends of the corresponding harness.

Visually inspect that there is neither rust nor foreign matter trapped at connector terminals. Inspect that there is no loosening or damage at the locked portion. Also, lightly pull the wire harness from the connector to check that it does not come off. Insert a male terminal same as that of the connector to a female terminal and check the extracting force. Defective contact may exist at a terminal where the extracting force is less than that of other terminals. Note:

Even if there is rust or foreign matter trapped at the terminal, or the contact pressure between male and female terminals is low, abnormal contact condition may be changed to normal by disconnecting and reconnecting the connector. In that case, repeat connector connection and disconnection several times. If defect is perceived even once, terminal contact may be defective.