2-19 2. CO (overall capacitor) (1) Inspection method Confirm complete discharge of CO before inspection. Standard: Bring tester probes into contact with both terminals of CO. The pointer once reflects to the 0 Ω side. Then it gradually returns to and finally indicates . is indicated because the capacitor is charged by the tester current. CO 3. TMD (drive motor transistor), TMP (pump motor transistor) (1) Inspection method Remove CO (overall capacitor) and the insulation cover.
15 ~ 32 model TMP (Only chopper) 35 ~ 55 model (For traveling) TMD TMD TMD2 Portion to be inspected Measurement terminals Tester range CO Both terminals on the rear side of CO Ω × 1k Portion to be inspected Measurement terminals Standard Tester range TMD TMP D1 (D2) (+) - S1 (S2) (-) D1 (D2) (+) - G (-) S1 (S2) (+) - D1 (D2) (-) S1 (S2) (+) - G (-) G (+) - D1 (2) (-) G (+) - S1(S2) (-) Approx. 2 kΩ Approx. 12 kΩ ∞ Ω Approx. 10 kΩ ∞ Ω Approx. 1 kΩ Ω × 1k