2-35 CN106 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) CN107 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) Connector No.⇔Connector No. Conditions Standard Remarks CN105-12 Unused ⎯ CN105-13 Unused ⎯ CN105-14 Unused ⎯ Connector No.⇔Connector No. Conditions Standard Remarks CN106-1 Unused ⎯ CN106-2 (27, CHOPB) Immeasurable ⎯ CN106-3 (28, CHOPP) Immeasurable ⎯ CN106-4 (29, CHOPS) Immeasurable ⎯ CN106-5 (31, OCL) Immeasurable ⎯ CN106-6 Unused ⎯ CN106-7 (32, TMPAD-) Immeasurable ⎯ CN106-8 CN104-17 (33, TMPD+) (N2, N2) Approx.
5 V CN106-9 CN104-17 (35, CKPV) (N2, N2) Approx. 10 V CN106-10 Unused ⎯ CN106-11 Unused ⎯ Connector No.⇔Connector No. Conditions Standard Remarks CN107-1 CN104-17 (26, TMDU+) (N2, N2) Approx. 5 V CN107-2 CN104-17 (20, TMDAU-) (N2, N2) Approx. 5 V CN107-3 CN104-17 (21, TMDBU-) (N2, N2) Approx. 5 V CN107-4 CN104-17 (22, TMDCU-) (N2, N2) Approx. 5 V CN107-5 CN104-17 (23, TMDAD-) (N2, N2) Approx. 5 V CN107-6 CN104-17 (24, TMDBD-) (N2, N2) Approx. 5 V CN107-7 CN104-17 (25, TMDCD-) (N2, N2) Approx. 5 V CN107-8 CN104-17 (26, TMDD+) (N2, N2) Approx. 5 V CN107-9 CN104-17 (34, CKDV) (N2, N2) Approx. 10 V CN107-10 Unused ⎯