2-47 CN103 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) CN104 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) Connector No.⇔Connector No. Conditions Standard Remarks CN103-1 CN103-2 (3, MP1+) (4, MP1-) Measurement with (-) probe in contact with CN103-2 Approx. 11 V CN103-2 CN103-1 (4, MP1-) (3, MP1+) Battery plug disconnected Resistance measurement Approx. 20 Ω CN103-3 CN104-10 (41, B48V) (N2, N2) Approx. 36 V Approx. 48 V CN103-4 CN104-10 (43, VBKY) (N2, N2) Approx. 36 V Approx.

48 V CN103-5 (5, MP2+) Immeasurable ⎯ CN103-6 CN103-5 (6, MP2-) (5, MP2+) Battery plug disconnected Resistance measurement Approx. 20 Ω CN103-7 CN104-10 (41, VBBT) (N2, N2) Approx. 36 V Approx. 48 V CN103-8 Unused ⎯ CN103-9 Unused ⎯ CN103-10 CN104-10 (16, D15V) (N2, N2) 14 ~ 15 V CN103-11 Unused ⎯ CN103-12 CN104-10 (14, GNDD) (N2, N2) Approx. 0 V CN103-13 (144, SMTDK) Immeasurable ⎯ CN103-14 (143, SDTMK) Immeasurable ⎯ CN103-15 (142, SDTMA) Immeasurable ⎯ CN103-16 (141, SMTDA) Immeasurable ⎯ Connector No.⇔Connector No. Conditions Standard Remarks CN104-1 CN104-10 (N2, N2C) (N2, N2) Approx. 0 V CN104-2 CN104-10 (54, CSBATT) (N2, N2) Approx.

7 V CN104-3 (19, CHOPD2-) 4 ~ 5 V CN104-4 Unused ⎯ CN104-5 CN104-10 (75, CSD+) (N2, N2) 14 ~ 15 V CN104-6 CN104-10 (75, CSD2+) (N2, N2) 14 ~ 15 V