Toyota — Toyota Equipment Manual (EN)

2-55 Contactor panel (35 ~ 55 model) CN134 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) CN136 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) CN137 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) Connector No.⇔Connector No. Conditions Standard Remarks CN134-1 CN134-2 (2, MD1-) (1, MD1+) Battery plug disconnected Resistance measurement Approx. 20 Ω CN134-2 CN134-1 (1, MD1+) (2, MD1-) Approx. 11 V Connector No.⇔Connector No.

Conditions Standard Remarks CN136-1 CN136-2 (101, LAMP+) (41, B48V) Battery plug disconnected Continuity CN136-2 (41, B48V) Immeasurable ⎯ CN136-3 (N2, N2) Immeasurable ⎯ CN136-4 CN137-8 (303, VBMB2) (44, VBMB) Battery plug disconnected Continuity Connector No.⇔Connector No. Conditions Standard Remarks CN137-1 (N2, N2) Immeasurable ⎯ CN137-2 CN137-3 (2, MD1-) (1, MD1+) Battery plug disconnected Resistance measurement Approx. 20 Ω CN137-3 CN137-2 (1, MD1+) (2, MD1-) Approx. 11 V CN137-4 CN137-7 (6, MP2-) (5, MP2+) Battery plug disconnected Resistance measurement Approx.

20 Ω CN137-5 CN137-1 (44, VBMB) (N2, N2) 36/48 V CN137-6 (19, CHOPCD-) Immeasurable ⎯ CN137-7 CN137-4 (5, MP2+) (6, MP2-) Approx. 11 V CN137-8 CN137-9 (44, VBMB) (N2, N2) 36/48 V CN137-9 (N2, N2) Immeasurable ⎯ CN137-10 CN137-11 (4, MP1-) (3, MP1+) Battery plug disconnected Resistance measurement Approx. 20 Ω CN137-11 CN137-10 (3, MP1+) (4, MP1-) Approx. 11 V CN137-12 (77, THC+) Immeasurable ⎯