Cold Starting Aid 16.2.3 Ether Start Installation The continuous flow ether system is available as an optional attachment on the industrial engine price list. The component in the ether system that controls ether quantity and spray angle is the atomizer. The atomizer has a control orifice that is sized for a specific range of intake air flow. Be sure to order the correct ether system to match the engine. NOTE: Ether atomizer location is critical to proper operation of each engine model’s cold start strategy. For proper ether atomizer location, specific to each engine model, consult with the Application Support Center.
The ECU can activate the ether control valve solenoid with a direct connection from ECU to the solenoid. Older systems required the use of a relay to switch battery supply to the solenoid, but the relay is no longer required due to more efficient solenoids and the higher current capability of the ECU driver. NOTE: The ECU will source 2.0 amps at normal operating conditions. At cold operating conditions, the ECU may source as low as 1.0 amp to the solenoid or relay. Caterpillar Industrial Price List components have been selected to operate in this 1.0-2.0 amp range. Ether Control Valve P1/J1 ECU Negative Battery (1) Refer to the appropriate parts manual for your engine.
(2) Fabricated to length 16.3 Air Inlet Heater (C7 ACERT and C9 ACERT Engines Only) 16.3.1 Air Inlet Heater Operation The Inlet Air Heater (IAH) is used to improve cold starting of the engine. The ECU controls the IAH through the inlet air heater relay. The heater and relay are installed on the engine at Caterpillar. An air inlet heater and a continuous flow ether starting aid system can be installed on the same engine. The ECU start aid strategy controls device priority so that these devices cannot operate at the same time. The Inlet Air Heater operation is determined at five different stages: Power-Up, Preheat, Engine Cranking, Engine Running, and Post Heat.
The trip point temperature for the various stages of air inlet heater operation is determined by the sum of the coolant temperature and the inlet air temperature. A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 111 10 REQUIRED PARTS Part Number Description Qty (1) Ether Control Valve 1 (1) Terminal 2 9X-3402 Connector Socket 1 N/A 16 AWG Wire (2)