Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual (EN)

Cold Starting Aid NOTE: If a block heater is used, and if the sum of coolant temperature and air temperature is greater than 64° C, then the air inlet heater will not operate. NOTE: DO NOT convert the sum of the temperatures!!! The temperatures MUST be converted before summing! The ECU adds coolant temperature and inlet manifold air temperature as measured in centigrade. In order to get the correct conversion of the summed value in Fahrenheit, each temperature must first be converted to Fahrenheit and then added together as follows: ([Coolant Temperature °C] x 1.8 + 32) + ([Inlet Manifold Air Temperature °C] x 1.8 + 32) = sum in Fahrenheit.

Following is an overview of the air inlet heater operation at the five stages of a normal start: 1. Power-up cycle. The heater and wait-to-start lamps will turn ON, and then turn OFF after two seconds if the temperature conditions for preheat are not met. The power-up cycle is essentially a component check. This will happen regardless of the temperatures or engine speed. 2. Preheat cycle. If the sum of the coolant temperature and inlet manifold air temperature is less than 64° C (147° F), the ECU will turn the inlet air heater relay output and wait-to-start lamp ON for up to 30 seconds as a preheat cycle.

If the operator attempts to start the engine before the preheat cycle ends, the ECU will continue to control the heater during engine cranking cycle. The wait-to-start lamp will turn OFF when engine speed is detected. The heater and lamp are turned OFF after a maximum of 30 seconds if the engine speed is still 0 rpm, regardless of the temperature. 3. Engine cranking cycle. When the engine is cranking, the heater will turn ON if the sum of the coolant temperature and inlet manifold air temperature is less than 147° F or 64° C and will stay ON while cranking. If the engine fails to start, the preheat cycle is restarted. 4. Engine running cycle.

After the engine has achieved low idle speed, the IAH operation is determined by the same combination of both the inlet manifold air temperature and coolant temperature. If the temperature conditions are met, the heater may be ON for a maximum of seven minutes. The inlet air heater will turn OFF anytime the sum of the inlet manifold air temperature and coolant temperature exceeds 147° F or 64° C. If the engine stalls or stops, the preheat cycle is restarted. 5. Post-heat cycle. If after the seven-minute engine running cycle the coolant temperature and air temperature are below 147° F or 64° C, then the heater is cycled on and off for an additional 13 minutes.

The cycle is 10 seconds ON and 10 seconds OFF. If there are logged faults on both the coolant temp sensor and the inlet manifold air temperature sensor, the ECU will not activate the air inlet heater. Whenever there is an active diagnostic code for the coolant temperature sensor, the heater will activate if the inlet manifold air temperature is less than 10° C (50° F). For an active inlet manifold air temperature sensor diagnostic, the heater will activate if coolant temperature is less than 40° C (104° F). I N D U S T R I A L E N G I N E E L E C T R O N I C S 112