Cold Starting Aid 16.3.2 Air Inlet Heater Configuration The “Air Inlet Heater Installation Status” must be programmed to “Enabled” via Cat ET if an air inlet heater is installed. This allows the ECU to control the inlet air heater. The default on C7 and C9 engines is “Enabled.” 16.3.3 Air Inlet Heater Installation Install the wait-to-start lamp. Refer to the wait-to-start lamp installation instructions in the “Starting and Stopping the Engine” section. The customer is responsible for connecting the contact side of the inlet air heater relay to battery voltage. Recommended circuit protection for this connection is 130 amps with a circuit load of 100 amps continuous.

The inlet air heater relay has a maximum “ON” time of seven minutes. Minimum required wire size is 4 AWG. The battery supply wire must be secured and not attached to a fuel line. Secure the wire with the clip before applying the proper torque of 9.0 Newton-Meters (N•m) +/- 1.0 N•m to the wire terminal at the terminal stud. Wire terminal nuts and locking washers are supplied with the relay. Caterpillar recommends the use of a breaking torque wrench such as the Mountz TLS-1360. CAUTION: Not meeting the specified torque limit may cause electrical arcing due to a mechanical failure of the relay stud or a loose connection.

A boot must be installed on the battery connection to the inlet air heater relay to help prevent electrical arcing. This boot must be made of heat-resistant material that can meet the UL94V0 rating for flammability. Choose terminals made of tin-plated brass with a hole size that is closest to the diameter of the stud (5/16 inch). The terminal hole should provide enough clearance to make assembly easy while maintaining contact. Caution must be taken to prevent the terminal from causing a short to chassis ground. Caterpillar recommends that the terminal ring connection to the battery supply wire be made with a bare terminal and then insulated using a sealed heat shrink.

A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 113 Battery Cable Air Inlet Heater