N40469 Chapter 3 Circuit breakers Cautions: • Always fit the correct breaker. Damage to the wiring loom may occur if a higher rated breaker is fitted. • Always find the cause of a breaker failure and correct the fault. If in doubt, consult an electrician at your nearest Perkins distributor. A wiring loom, which includes a breaker panel to protect the wiring from damage by a short circuit, has been fitted to your engine. The breaker panel is below the exhaust manifold and above the oil filter and has the following breakers: • 10Amp - start Figure 8 • 105Amp - glow plugs Should a breaker trip, it will stand proud of the panel and it can be reset by pushing it in. Warning!