Emergency stop Emergency stop at terminal box A series feature of the terminal box is an emergency stop switch with detends. If this switch is actuated the engine switches itself off and the starter motor can no longer be triggered. The switch must be unlocked before the engine is started again. Connection of emergency stop system at bridge and flybridge Additional emergency stop switches for the bridge and flybridge can be installed between terminal 30 (+) and terminal 30n. In some cases such emergency stop switches are mandatory in conjunction with electric throttle lever systems. If no further emergency stop switches are installed, terminal 30 and terminal 30n are to be bridged together.
The bridge for this is provided in the terminal box. If the emergency stop switch is actuated no entry is made in the EDC control unit’s fault memory, as tracking of the EDC control unit is ensured even if the emergency stop switch is actuated. Fig. Kl. 30n Emergency stop Bridge Emergency stop 3 Emergency stop 2 Emergency stop switch Kl. 30 (+) Terminal box 95