92 Maintenance Section Backup Alarm - Test Note: The oscillation bearings are lubricated by using two remote grease fittings. These fittings are located behind the small access door on the left side of the machine. 1. Wipe all fittings before any lubricant is applied. 2. Fitting (1) lubricates the front oscillation bearing of the rear axle. Fitting (2) lubricates the rear oscillation bearing of the rear axle. i01713195 Backup Alarm - Test SMCS Code: 7406-081 1. Turn the engine start switch key to the ON position in order to perform the test. 2. Apply the service brake. g00782208 Illustration 132 The alarm should start to sound immediately.
The alarm will continue to sound until the transmission direction control lever is moved to the NEUTRAL position or to the FORWARD position. Reference: For more information, refer to Operation and Maintenance Manual, “Backup Alarm”. i01558375 Battery - Clean SMCS Code: 1401-070 g00783907 Illustration 131 3. Move the transmission direction control lever to the REVERSE position. g00809805 Illustration 133