Cummins — AIR COMPRESSOR COOLANT OUTLET TUBE - INSTALLATION

Section 0 - Engine Disassembly and Assembly - Group 00 Engine Assembly (0-02) M11 Page 0-131 Install the fuel suction line from the electronic control cooling plate (1) to the filter head (2). Starting Motor - Installation The mounting capscrews for the starting motor will be metric (M16-2.00 x 45) 12 point, or U.S. Customary (5/8-11 x 3/4) hex head, depending on the flywheel housing used. Make sure to use the correct capscrews to avoid damage to the threaded holes in the flywheel housing. Install the spacer if required. Install the starting motor into the flywheel housing bore with the three capscrews. Torque Value:

90 [140 ft-lb] Air Compressor Coolant Outlet Tube - Installation Remove capscrew (1) from the gear cover. Use the capscrew to install the coolant outlet clamp and tube to the engine. Torque Value: 20 [15 ft-lb] Install a new rubber grommet on the air compressor tube, and install and tighten the tube connection to the air compressor fitting (2). Torque Value: 20 [15 ft-lb] Fan Hub Support - Installation Install the fan hub support with three capscrews (M12- 1.75 x 80). Torque Value: 75 [55 ft-lb]