John Deere 450DLC — Main Controller (MCF) Circuit Theory of Operation

TM2361 (24JUN08) 9015-15-29 450DLC Excavator Operation and Tests 062608 PN=473 Sub-System Diagnostics • Pump 2 delivery pressure sensor (B37) • Travel Speed Solenoid (Y25) (SI) • Pump 2 control pressure sensor (B38) • Reversing Fan Solenoid (Y8) (optional) MCF outputs involved: Boom Flow Rate Solenoid (Y22) (SF): The boom flow rate control restricts main pump pressure oil to the • Pump 1 control solenoid (Y12) boom cylinder during boom lower operation when • Pump 2 control solenoid (Y13) combined with any of the arm or bucket functions.

When the boom is lowered, it uses its own weight and When the attachment function is operated, attachment the boom regenerative circuit to assist in this pressure sensor (B45) detects attachment pilot operation. pressure and sends a corresponding signal to terminal D10 on the MCF. MCF inputs involved: NOTE: When in dig mode, the maximum flow setting • Boom down pressure sensor (B53) is 367 L/min (97 gpm). • Arm out pressure sensor (B50) • Arm in pressure sensor (B51) When in attachment mode, the maximum flow • Bucket curl pressure sensor (B54) depends on settings inputted in the monitor • Bucket dump pressure sensor (B55) controller. See Pump 2 Flow Rate Adjustment.

(Operator’s Manual.) MCF output involved: Boom flow rate solenoid (Y22) When the MCF receives a signal from the monitor When the MCF detects signals from boom down controller indicating the attachment mode has been pressure sensor (B53) and one of the arm or bucket selected, the MCF will compare the actual swash plate pressure sensors (B50, B51, B54, or B55) to indicate angle of pump 2 [by signals it receives from pump 2 combined operation of boom lower and arm (or control pressure sensor (B38)] with the maximum bucket), the MCF sends current out terminals A3 and pump 2 flow rate setting selected on the monitor A20 to boom flow rate solenoid (Y22), energizing the controller.

The MCF then sends the appropriate solenoid. With the boom flow rate solenoid energized, amount of current to pump 2 control solenoid (Y13) to most of the pressure oil from the main pump is compensate for the difference. diverted to the other circuit being actuated, causing operating speed of the other actuator to increase. During operation of the attachment, the return oil from the attachment does not flow through the oil cooler, For hydraulic information on this circuit, see Boom but instead, flows directly to the hydraulic oil tank. To Flow Rate Circuit Operation.

(Group 9025-05.) increase oil flow through the oil cooler and prevent overheating of the hydraulic oil during attachment Boom Mode Solenoid (Y23) (SC): The boom mode operation, the MCF increases output current to pump 1 control reduces vibration of the machine when digging control solenoid (Y12). This increases the delivery flow and grading. It does this by reducing the overload rate of pump 1, which causes more oil to flow through relief valve pressure to 11 800 kPa (118 bar) (1712 the oil cooler. psi). The normal overload relief valve pressure is 35 300 kPa (353 bar) (5120 psi). Valve Control—The valve control involves the following solenoids: MCF inputs involved:

• Boom Flow Rate Solenoid (Y22) (SF) • Boom mode switch (S20) • Boom Mode Solenoid (Y23) (SC) • Swing pressure sensor (B33) • Power Dig Solenoid (Y24) (SG) • Attachment pressure sensor (B45) Continued on next page CS33148,00008EB –19–28APR06–12/15 9015 15 29