John Deere 450DLC — No Hydraulic Functions Diagnostic Procedure

Group 15 Diagnostic Information Diagnose No Hydraulics Malfunctions MR50960,00000F5 –19–21APR06–1/1 No Hydraulic Functions Diagnostic Procedure IMPORTANT: Check hydraulic oil level. See Check Hydraulic Tank Oil Level. (Operator’s Manual.) –1/1 TM2361 (24JUN08) 9025-15-1 450DLC Excavator Operation and Tests 062608 PN=751 1 Pilot Shutoff Lever Switch Check Key on, listen as pilot shutoff lever is moved from locked to unlocked positions. Repeat lever movement locked to unlocked several times. Does pilot shutoff switch click each time lever is moved from locked to unlocked position? YES: Go to Security Switch Relay Check. NO: Go to Pilot Shutoff Relay Check.

– – –1/1 2 Pilot Shutoff Relay Check See System Functional Schematic. (Group 9015-10.) Switch pilot shutoff relay K2 with other similar relay. Run engine with pilot shutoff lever in unlocked position and operate hydraulic functions. Do hydraulics operate? YES: Install new pilot shutoff relay K2 and return other one to correct position. NO: Go to Security Relay Check. – – –1/1 9025 15 1 3 Security Relay Check See System Functional Schematic. (Group 9015-10.) Switch security relay K5 with other similar relay. Run engine with pilot shutoff lever in unlocked (forward) position and operate hydraulic functions. Do hydraulics operate? YES:

Install new security shutoff relay K5 and return other one to correct position. NO: Go to Pilot Shutoff Solenoid Check. – – –1/1