John Deere 450DLC — No Hydraulic Functions Diagnostic Procedure

TM2361 (24JUN08) 9025-15-2 450DLC Excavator Operation and Tests 062608 PN=752 Diagnostic Information 4 Pilot Shutoff Solenoid Check See System Functional Schematic. (Group 9015-10.) Remove connector from pilot shutoff solenoid valve. Key on, test voltage on terminal #2 at the harness end connector. Does terminal #2 measure approximately 24 volts? YES: Go to Solenoid Continuity Check. NO: Failed fuse #4 or open circuit in harness between fusible link 75A and pilot shutoff solenoid valve. – – –1/1 5 Solenoid Continuity Check See System Functional Schematic. (Group 9015-10.) Remove connector from pilot shutoff solenoid valve.

Check for continuity between terminals #1 and #2 of the solenoid valve harness connector. Is continuity measured? YES: Go to Wiring Connector Check. (Group 9025-15.) NO: Replace pilot shutoff solenoid valve. – – –1/1 6 Pump Drive Check See Dampener Drive (Flex Coupling) Remove and Install. (Group 0752.) Check dampener drive coupling. Does dampener drive (flex coupling) drive pumps? YES: Go to Hydraulic Oil Tank Suction Screen Check. NO: Repair or replace dampener drive (flex coupling). – – –1/1 9025 15 2 7 Hydraulic Oil Tank Suction Screen Check See Change Hydraulic Tank Oil, Clean Suction Screen. (Operator’s Manual.) Inspect hydraulic oil tank suction screen.

Is hydraulic oil tank suction screen free of restriction? YES: Go to Wiring Connector Check. NO: Clean or replace hydraulic oil tank suction screen. See Change Hydraulic Tank Oil, Clean Suction Screen. (Operator’s Manual) – – –1/1