John Deere 450DLC — Some Functions Cannot Be Operated or Are Slow, Travel And Swing Are Normal Diagnostic Procedure

Some Functions Cannot Be Operated or Are Slow, Travel And Swing Are Normal Diagnostic Procedure NOTE: If travel and swing are normal, the pilot pump pressure is assumed to be normal in this diagnostic procedure. –1/1 TM2361 (24JUN08) 9025-15-18 450DLC Excavator Operation and Tests 062608 PN=768 Diagnostic Information 3 Power Boost Pressure Check Key on, use monitor service menu to display Pump 1 or Pump 2 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Put power mode switch on HP and work mode on digging. Run engine at fast idle and take arm-in function over relief. Record pressure. Push and hold power dig switch on control lever and observe monitor.

Does pump 1 and 2 delivery pressure increase approximately 2.5 MPa when power dig switch held on? YES: Diagnose problem in main controller. See Main Controller (MCF) Diagnostics Using Dr. ZX. (Group 9015-20.) NO: Replace or adjust main relief valve. See Main Relief and Power Digging Valve Test and Adjustment. (Group 9025-25.) – – –1/1 1 Actuating Pilot Pressure Check Key on, use monitor service menu to display Swing / Attachment Control Pilot Pressure. See Monitor Service Menu Operation. (Group 9015-16.) NOTE: Spool actuating pressure can be checked for each function by installing a tee and gauge in pilot line and then actuating that function.

Perform Control Valve Spool Actuating Pilot Pressure Test. (Group 9025-25.) Run engine at fast idle and operate problem function. Observe pressure when function held over relief. Is pilot pressure above 3.70 MPa? YES: Go to Pump Control Pressure Check. NO: If boom operation is abnormal, repair pilot valve or shockless valve spool. See Pilot Signal Manifold Disassemble and Assemble. (Group 3360.) – – –1/1 9025 15 18 2 Pump Control Pressure Check Key on, use monitor service menu to display Pump 1 and Pump 2 Control Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Run at fast idle and observe pressure on monitor as problem function control lever is moved slowly.

Does pump control pressure change smoothly when lever is slowly moved? YES: Go to Circuit Relief Valve Check. NO: Repair shuttle valve in pilot signal manifold. See Pilot Signal Manifold Disassemble and Assemble. (Group 3360.) – – –1/1