TM2361 (24JUN08) 9025-15-21 450DLC Excavator Operation and Tests 062608 PN=771 Diagnostic Information 1 Actuating Pilot Pressure Check Key on, use monitor service menu to display Swing / Attachment Control Pilot Pressure. See Monitor Service Menu Operation. (Group 9015-16.) NOTE: Spool actuating pressure can be checked for each function by installing a tee and gauge in pilot line and then actuating that function. Perform Control Valve Spool Actuating Pilot Pressure Test. (Group 9025-25.) Run engine at fast idle and operate problem function. Observe pressure when function held over relief. Is pilot pressure above 3.70 MPa? YES: Go to Combined Function Control Pressure Check. NO:
If boom operation is abnormal, repair pilot valve or shockless valve spool. See Pilot Signal Manifold Disassemble and Assemble. (Group 3360.) – – –1/1 2 Combined Function Control Pressure Check. Install pressure gauge on bucket flow rate control valve port (2). 1 2 3 TX1006257 –UN–12APR06 1—Pilot Signal Manifold 2—To Bucket Flow Rate Control Valve 3—To Travel Flow Combiner Valve Run engine at fast idle and operate boom raise and arm-in over relief. Is pressure approximately 3.9 MPa, (3 900 kPa) (39 bar) (570 psi)? YES: Go to Arm Regenerative Valve Check. NO: Repair or replace pilot valve. – – –1/1 9025 15 21 3 Arm Regenerative Valve Check. See Control Valve Operation.
(Group 9025-05.) Inspect arm regenerative valve. Is valve bound or scored? YES: Repair or replace arm regenerative valve. NO: Repair arm control valve spool. See Control Valve 5-Spool Disassemble and Assemble. (Group 3360.) – – –1/1