John Deere 450DLC — Load Falls When Control Valve Is Actuated To Raise Load With Engine Running At Slow Idle Diagnostic Procedure

Load Falls When Control Valve Is Actuated To Raise Load With Engine Running At Slow Idle Diagnostic Procedure –1/1 TM2361 (24JUN08) 9025-15-23 450DLC Excavator Operation and Tests 062608 PN=773 Diagnostic Information 4 Boom Overload Relief Check Key on, use monitor service menu to display Pump 1 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Put boom mode switch in on position. Run engine at fast idle and lower boom to raise one track off ground. Record maximum pressure. Does delivery pressure stop at approximately 14.0 MPa? YES: Diagnostic procedure complete. NO: Go to Boom Mode Switch Exchange Check.

(Group 9025-15.) – – –1/1 5 Boom Mode Switch Exchange Check See System Functional Schematic. (Group 9015-10.) Swap boom mode switch S20 with engine fluid level check switch S21. Does machine now raise off ground? YES: Replace boom mode selector switch. NO: Go to Continuity Check. – – –1/1 6 Continuity Check See System Functional Schematic. (Group 9015-10.) Disconnect boom mode switch and connector B in main controller. Check for continuity between terminal #9 harness end connector and terminal #2 of harness and end connector B at main controller. Is continuity measured? YES: Diagnose problem in main controller. See Main Controller (MCF) Diagnostics Using Dr. ZX. (Group 9015-20.). NO:

Open circuit in harness, replace or repair as required. – – –1/1 9025 15 23 7 Circuit Relief Valve Check Key on, use monitor service menu to display Pump 1 or Pump 2 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Put power mode switch on HP and work mode on digging. Run engine at fast idle and operate each digging function over relief. Record pressure. Do all circuit relief valve above 30.4 MPa? YES: Diagnostic procedure complete. NO: Adjust or repair circuit relief. Perform Circuit Relief Valve Test and Adjustment. (Group 9025-25.) – – –1/1