TM2361 (24JUN08) 9025-25-2 450DLC Excavator Operation and Tests 062608 PN=862 Tests JT02156A Digital Pressure/Temperature Analyzer Installation SERVICE EQUIPMENT AND TOOLS JT02156A Digital Pressure/Temperature Analyzer JT02158 Digital Pressure/Temperature Analyzer –UN–25AUG95 JT02159 20 ft Cable with Couplers JT02161 500 psi Transducer JT02162 5000 psi Transducer T8543AI JT05969 Thermo-Coupler 312883 Carry Case JT02160 10,000 psi Transducer (Optional, Order Separately) A—Digital Pressure/Temperature Analyzer B—3 400 kPa (35 bar) (500 psi) Transducer Use the digital pressure/temperature analyzer (A), and —34 000 kPa (350 bar) (5000 psi) Transducer transducers (B) in place of analog gauges and a separate —70 000 kPa (700 bar) (10,000 psi Transducer temperature reader.
Transducers are temperature sensitive. Allow transducer to warm to system temperature. After transducer is warmed and no pressure applied, push sensor zero button for one second to set the true zero point. When using for different pressures, turn selector to OFF for two seconds and then to the pressure range. Readings are inaccurate if proper range for transducer is not used. 9025 25 2 CED,TX08227,2896 –19–02JUL01–1/1