John Deere 450DLC — Hydraulic Oil Warm-Up Procedure

Tests Hydraulic Oil Warm-Up Procedure do this could cause pump cavitation. Once oil temperature is above -18 ° C (0 ° F), the power mode can be switched to HP mode (high power). Below -18 ° C (0 ° F) an extended warm-up period may be necessary. Hydraulic functions will move slowly and lubrication of parts may not be adequate with cold oil. Do not attempt normal machine operation until hydraulic functions move at or close to normal cycle times. Operate functions slowly and avoid sudden movements until engine and hydraulic oils are thoroughly warmed. Operate a function by moving it a short distance in each direction.

Continue operating the function increasing the distance traveled in each cycle until full stroke is reached. IMPORTANT: If machine temperature is below -18 ° C (0 ° F), start procedure in the E power mode (economy). Failure to For faster warm-up, restrict air flow through oil cooler using cardboard or other similar material. Use correct viscosity oil to minimize warm-up period.

Continued on next page TX04577,00000E7 –19–05JUN06–1/4 9025 25 4 TM2361 (24JUN08) 9025-25-4 450DLC Excavator Operation and Tests 062608 PN=864 SPECIFICATIONS Engine Speed 1/2 Speed if below -18°C 1/2 Speed if below 0°F Fast Idle if above -18°C Fast Idle if above 0°F Power Mode Switch Position E Mode (Economy) if below -18°C E Mode (Economy) if below 0°F HP Mode (High Power) if above -18°C HP Mode (High Power) if above 0°F Work Mode Switch Position Dig Mode Auto Idle Switch Position OFF Travel Speed Switch Position Slow (Turtle) Hydraulic Oil Temperature 45—55°C 110—130°F