TM2361 (24JUN08) 9025-25-9 450DLC Excavator Operation and Tests 062608 PN=869 Tests Remove pilot hose at test port location (1) at filter housing. Install 203836 tee in-line. Connect the JT02156A Digital Pressure/Temperature Analyzer and JT02160 35 000 kPa (350 bar) (5000 psi) transducer or a 70 000 kPa (700 bar) (10,000 psi) gauge. See JT02156A Digital Pressure/Temperature Analyzer Installation for instruction. 2. Warm hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure. (Group 9025-25.) 3. Run machine at specification: Specification Hydraulic Oil—Temperature........................................................
45—55°C 110—130°F Engine—Speed..................................................... Fast Idle and Slow Idle Work Mode Switch—Position...................................................... Dig Mode Power Mode Switch—Position.....................................P (Standard) Mode Auto-Idle Switch—Position.................................................................... Off 4. Operate arm in to full stroke with engine speed at slow idle. Record monitor and gauge pressure readings. 5. Operate arm in to full stroke with engine speed at fast idle. Record monitor and gauge pressure readings. 6. Compare pressure readings to specifications.
Specification Pilot System—Pressure.................................... 3.7—4.6 MPa at Slow Idle 3700—4600 kPa at Slow Idle 37—46 bar at Slow Idle 540—668 psi at Slow Idle Pilot System—Pressure................................... 3.7— 4.1 MPa at Fast Idle 3772—4118 kPa at Fast Idle 37.7—41.2 bar at Fast Idle 526—594 psi at Fast Idle Continued on next page TX04577,00000EB –19–05JUN06–3/4 9025 25 9