John Deere 450DLC — Power Dig Solenoid Valve (port SG) Test and Adjustment

TM2361 (24JUN08) 9025-25-17 450DLC Excavator Operation and Tests 062608 PN=877 Tests 7. Push the power dig switch. Record pressure readings from monitor and gauge. 8. Calculate the pressure range using the calculated reading from monitor and the specify tolerance. Check that the actual reading from gauge is within the pressure range. Specification Power Dig Solenoid Valve (port SG)—Pressure............................................... Monitor Reading ± 0.2 MPa Monitor Reading ± 200 kPa Monitor Reading ± 2.0 bar Monitor Reading ± 29.0 psi Actual Reading From Gauge Must Be Within Pressure Range of Monitor Reading and Tolerance.

Example of Calculated Reading From Monitor Actuated Neutral Example of 2.15 MPa 0.50 MPa Calculated Reading 2150 kPa 500 kPa From Monitor 21.5 bar 5.0 bar 312.0 psi 73 psi Continued on next page LD30992,00002B1 –19–05JUN06–4/5 9025 25 17 Example of Calculated Reading From Monitor Actuated Neutral Example of Calculated Reading From Monitor 2.15 MPa 2150 kPa 21.5 bar 312.0 psi 0.50 MPa 500 kPa 5.0 bar 73 psi