Tests Refrigerant Hoses and Tubing Inspection IMPORTANT: Hose used for air conditioning systems contains special barriers in its walls to prevent migration of refrigerant gas. DO NOT use hydraulic hoses as replacement hoses in the air conditioning system. Use ONLY certified hose meeting SAE J51B requirements. When a component is disconnected from the system, special care should be given to inspecting hoses and tubing for moisture, grease, dirt, rust, or other foreign material. If such contamination is present in hoses, tubing, or fittings and cannot be removed by cleaning, then replace parts. Fittings that have grease or dirt on them should be wiped clean with a cloth dampened with alcohol.
Chlorinated solvents (such as trichloroethylene) are contaminants, and must not be used for cleaning. To assist in making leak-proof joints, use a small amount of clean correct viscosity refrigerant oil on all hose and tube connections. Dip O-rings in correct viscosity oil before assembling. LD30992,000049C –19–23MAR06–1/1 TM2361 (24JUN08) 9031-25-6 450DLC Excavator Operation and Tests 062608 PN=968 Air Conditioner Compressor Belt Check and Adjustment See Check and Adjust A/C Belt. (Operator’s Manual.) LD30992,000049D –19–23MAR06–1/1 9031 25 6