MAN — MAN MBE900 Operator's Guide (EN)

MAINTENANCE 1. Remove the cover of the oil centrifuge. See Figure 48. Keep the engine running at idling speed until an oil pressure reading is obtained. If no oil pressure is shown after approximately 10 seconds, stop the engine and determine the cause. Failure to do so could result in engine damage. NOTICE: 11. Start the engine with the accelerator pedal in the idle position. Monitor the oil pressure gauge. 12. Check the filter and oil drain plug for signs of leakage. Figure 48 Oil Centrifuge 2. Lift out the dirty cartridge and replace it with a clean one (see Figure 49). 13. Stop the engine. 14. Check the oil level again after approximately five minutes.

If necessary, add oil up to the maximum fill level on the oil dipstick. Do not overfill. Oil Centrifuge The MBE six-cylinder engines (906/926) have an oil centrifuge. NOTICE: Both the primary lube oil filter (front of engine) and the oil centriguge cartridge (side of engine) must be replaced at each oil drain interval. Figure 49 Centrifuge Cartridge 3. Replace the centrifuge cover, tighten the cap 40 Nm (30 lb·ft). Change the oil centrifuge cartridge as follows: 90 All information subject to change without notice. (Rev. 04/08) DDC-SVC-MAN-0055 04/08 Copyright © 2008 DETROIT DIESEL CORPORATION