Condition of the Engine Oil Pressure signal. The panel will display “ :C3:XX ” for 3 seconds, then indicate: C3:oo ” Engine is running. ” Engine is not running. Condition of Alternator ’R’ terminal signal. The panel will display “ C4:XX ” for 3 seconds, then indicate: C4:oo ” Engine is running. ” Engine is not running. Condition of the Spare Analog Input 1 signal. The panel will display “ C5:XX ” for 3 seconds with XX: as an input signal (V). Condition of the Spare Analog Input 2 signal. The panel will display “ C6:XX ” for 3 seconds with XX: as an input signal (V). Condition of the Spare Digital Input 1 signal. The panel will display “ C7:XX ” for 3 seconds, then: C7:oo ” High. ” Low.
Condition of the Spare Digital Input 2 signal. The panel will display “ C8:XX ” for 3 seconds, then: C8:oo ” High. ” Low. 4. Press the TOTAL/SFT switch to view faults again or press the MODE switch to return to normal operation. M20-22 Payload Meter II M20007.1 03/02