Cummins — Cummins HG190 и HG220 Двигатели Руководство (EN)

www.changlin.com.cn 13mm Install the belt tensioner. Torque Value: 43N*m [32ft-lb] Fan Pulley Replacement Preparatory Steps: Remove the drive belt. NOTE: Loosen the capscrews before removing the belt and torque the capscrews after the belt is installed. 13mm Remove the four capscrews, fan and spacer. Replace the fan pulley. Torque Value: 43N*m [32ft-lb] Water Pump Replacement Preparatory Steps: Drain the coolant. Remove the drive belt. 94 / 149 pages