Doosan DBC 130 / F30i Series — 1.1 2001 Emg. Button or Axes Emergency

DBC 130(F30i Series) DBC130ALE2A 1. Emergency Alarm 1.1 2001 Emg. Button or Axes Emergency 1) Description The Emergency Stop push-button switch on the operation panel is pressed down, or at least one Emergency Stop limit switch for the axes is tripped. 2) Cause of problem ① The Emergency Stop push-button switch on any of the main OP, the tool magazine OP, or the chip conveyor is pressed down. ② The Limit switch for an emergency stop located for each axis (X, Y, Z, W) is pressed down.

③ An error in the Emergency Stop switch on the OP, or the Emergency Stop limit switch for each axis, or other related parts ④ Disconnection of the wiring 3) Action ① Check if the red mushroom push-button switch on the main OP, the tool magazine OP, or the chip conveyor is pressed down, and if so, turn the switch counter clockwise to release it. ② If the Limit switch for any axis (X, Y, Z, or W) is tripped, press both the Machine Ready switch and the Emergency Release switch simultaneously to enter the Machine Ready state.

(If you want to return to the emergency stop state, simply release the switch.) Then, move the problem-making axis in jog or handle mode so as to remove it from the ③ Check the Emergency Stop push-button switch on the main OP, the Emergency Stop limit emergency stop limit switch. switch on the axis, and other related parts for any problem. Repair or replace the defective part if necessary. ④ Disconnection of the wiring Refer to the circuit diagram and use the electric tester to check each terminal block. If you find an error, repair or replace the defective part. 4 Part Name Part No. Symbol Spec.

Maker Switch, Emergency P/B ESWPB0439 SB1,7,9,61 B30-81L2B KACON Switch, Limit ESWLM0111 SL11.1,12.1,13.1,15.1 D4C-4332 OMRON Device Connector (Pin) Signal Address I/O Numbering Symbol Emergency Stop X8.4 ESP.M -SB1,7,9,10 I/O Module Slot 7 XJ413 (23) ESP