EVX Series EVX 1272 Datasheet 12V Top Terminal VRLA-AGM Valve Regulated Lead Acid (VRLA) Battery Maintenance-Free, Absorbent Glass Mat (AGM) Technology for Efficient Gas Recombination of up to 99% Pure Lead Construction and Proprietary Elements Designed for E-mobility or deep cycling applications Built in Accordance with IEC 60254-1:2005 / IEC60254- 2:2008 and UL1989 Recognized (MH14533) 11F, No. 150, Sec. 4, Chengde Rd., Shilin Dist., Taipei City 111052, Taiwan (R.O.C.) W W W. C S B - B AT T E RY . C O M Tel: +886-2-2880-5600 Mail:
service@csb-battery.com.tw RA240531 Specifications Voltage (Vdc) 12 Nominal Capacity (1.75 VPC @25°C) 7.2 Ah @20hr-rate Ah Capacity (8-Hr 1.75 VPC @ 25°C) 6.00 Ah Capacity (20-Hr 1.75 VPC @ 25°C) 7.20 Ah Capacity (8-Hr 1.80 VPC @ 25°C) 5.76 Max Charge Current (A) 2.16 Max Discharge Current (A) 130 * Short Circuit Current (A) 292 Internal Resistance (mΩ) Approx. 23.9 Terminal Type F2 terminal -Faston Tab 250 * Terminal Torque -- Container Material ABS (UL 94-HB) Weight (kg.
/ lb., Approx.) 2.55 / 5.62 Length (L) (mm / in) 150.9±2.0 / 5.94±0.08 Width (W) (mm / in) 64.8±1.0 / 2.55±0.04 Height (H) (mm / in) 98.6±1.0 / 3.88±0.04 Design Life 400 cycles @ 100%DOD at 25°C 1800 cycles @ 30%DOD at 25°C Operating Temperature Nominal: 25°C (77°F) Discharge: -15°C - 50°C (5°F-122°F) Charge/Storage: -15°C - 40°C (5°F – 104°F) Float Charging Voltage -- Eq. Charging Voltage 14.4 - 15.0 Vdc/battery 25°C (77°F) Self-Discharge Less than 10% after 90 days, can be stored up to 6 months at 25°C (77°F); Fully recharging is required before usage, and charged sooner if stored at higher temperature than 25°C (77°F).
EVX Series EVX 1272 Datasheet 12V Top Terminal VRLA-AGM 11F, No. 150, Sec. 4, Chengde Rd., Shilin Dist., Taipei City 111052, Taiwan (R.O.C.) W W W. C S B - B AT T E RY . C O M Tel: +886-2-2880-5600 Mail: service@csb-battery.com.tw RA240531 Constant Current Discharge Characteristics Unit: A (25°C, 77°F) F.V/Time 30MIN 45MIN 60MIN 90MIN 2HR 3H R 4HR 5HR 6HR 8HR 10HR 20HR 10.02V (1.67 VPC ) 6.79 5.01 4.04 2.98 2.40 1.7 3 1.39 1.16 1.00 0.79 0.65 0.38 10.50V (1.75 VPC ) 6.38 4.71 3.80 2.81 2.27 1.6 3 1.32 1.10 0.95 0.75 0.62 0.36 10.80V (1.80 VPC ) 6.20 4.58 3.70 2.73 2.19 1.5 8 1.28 1.07 0.92 0.72 0.60 0.35 Constant Power Discharge Characteristics Unit:
W (25°C, 77°F) F.V/Time 30MIN 45MIN 60MIN 90MIN 2HR 3H R 4HR 5HR 6HR 8HR 10HR 20HR 10.02V (1.67 VPC ) 81.4 60.3 48.8 35.8 28.8 20 .9 16.8 14.0 12.0 9.50 7.86 4.35 10.50V (1.75 VPC ) 76.8 56.8 45.9 33.8 27.1 19 .6 15.8 13.2 11.4 8.96 7.49 4.14 10.80V (1.80 VPC ) 74.4 55.0 44.4 32.7 26.2 19 .0 15.3 12.8 11.0 8.67 7.25 4.00 * F1 terminal is available, Max Discharge Current = 100 A (5sec)