EPSON — Mode setting for warning signal (output)

Chapter 3 Commands Mode setting for warning signal (output) [Format] ^S(CNA,W,c [Parameter] c [Function] Configure the mode settings for the warning signal. [Initial value] 0 [Examples of command transmissions] 3 Set the warning signal to "Normal: High, When a warning occurs: Low". The ^JUS command must be used to save the settings to the non-volatile memory in the printer. An example of the command transmission is shown below. It is sent via USB or Ethernet from the computer. ^XA ^S(CNA,W,1 ^JUS ^XZ 30 Description Definition range c = Mode setting D/E/0/1/2 Value for parameter c Description D/0 Turn the warning signal (pin 16) OFF (not output). 1 Set the warning signal (pin 16) as follows:

Normal: High, When a warning occurs: Low. E/2 Set the warning signal (pin 16) as follows: Normal: Low, When a warning occurs: High.