US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors (EN)

Downloaded from https://www.everyspec.com AMP 706-117 sampling high concentrations of large particles (Ref. sieving can be used to extend the lower limit to 37 20), and it is particularly well suited for high flow rates; э.m. Particle diameter has been defined in a number of e.g., a reasonably sized sample must be collected in a ways for the subsieve-sized pati~cles, and some of these short period of time when sampling vehicle-generated definitions extend into the sieve-sized range as well. dust clouds. (2) Microscopy. 4 Of the many different methods available for analyzing particle size, microscopy Is the 3-3.2 PARTICLE SIZE ANALYSIS 4 only direct method.

Microscopic measurements and 3-3.2.1 Means of Separation counts are extremely tedious and time consuming but reliable and reprodteilble If performed by experienced Particle size is basically determined by (I) sieving, (2) technicians. microscopy, (3) sedimentation or elutriation, and (4) The sizes of irregularly shaped particles, when deter- impaction. No one method is applicable for the overall mined by microscopic measurement, are stated as pro- size range of sand and dust. The first three methods are jected diameters or statistical diameters.

The projected suited best to analysis on a discrete sampling basis in diameter is the diameter of a circle equal in area to the an offstream environment. They cannot be applied to profile of the particle viewed normal to the position of airstream, real-time monitoring. In the fourth method, greatest stability. The two most commonly used statis- cascade impactors automatically separate the sample tical diameters are Feret's and Martin's diameters, as into particle size ranges; however, the deposited shown in Fig. 3-12. Feret's diameter is the mean of the material has to be removed for weighing and for any distances between two tangents on opposite sides of further analyses.

Impactors can be used onstream but each particle image in the sample, the tangents being not for real-time monitoring, A fifth method, radiatioh drawn perpendicular to the direction of traverse, Mar- scattering, is available for particle size analysis under tin's diameter is the mean of the lengths of a line that laboratory or controlled conditions, but because it is intercepts each particle image in the sample and divides not presently adaptable to field test conditions, it is not it into equal areas (A 1 and A,); the bisecting line is included in the following discussion. always parallel to the direction of traverse. Martin's (1) Sieving.

Dry sieving is usually the first step in size analysis of particles greater than 74 pm in diame- tei. Particle size is taken as the diametea" of a sphere that will just pass through the aperture of the smallest sieve. Sieving may be carried out with one sieve at a time or with a series of sieves, each having progres- sively smaller openings. The particles retained by each § ', -A 2 screen are weighed to give the particle size distribution MARTIN'S by weight of the sample.

The American Society for Testing and Materials (A) Martin's diameter measuring mean length of Standard STP 447, Manual on Test Sieving Methi- line dividing particle into equal areas ods, sets forth the proper methods for conducting sieve operations. Sieving is one of the oldest, most direct, and simplest means for determining the size and size distribution of sand and dust particles. Dry sieving is used universally in size differentiation of particles larger than 74 Am in diameter (Ref. 4).

The arithmetic mean diameter of a sieve sample is FERET'S the sum of the weight fractions retained on each sieve, multiplied by the corresponding diameter (taken as the (B) Feret's diameter measuring mean distance be. size of the openings of the last sieve the sample passed tween tangents on opposite aides of particle Image through) and then divided by the total weight of the sample. Particles that pass through a 74-Mim sieve are gener- ally referred to as subsieve particles, even though wet FIGURE 3-42. Particle Sizing Models (Each part/cle shown is representarlve of all partices In Mhe sample 4. A general reference for this paragraph is Ref. 21. which am measured and averaged.) 3.16