Downloaded from https://www.everyspec.com AMCP 706-117 diameter is slightly smaller than the mean projected analyses. By connecting several stages in series so that diameter, and Feret's is greater. The projected diameter each stage collects all particles above a certain cutoff more nearly corresponds to the Stokes' diameter diameter, the sample is separated into size groups. derived from sedimentation and clutriation measure- Seven stages have been successfully used for particle ments. size analysis (Ref. 21).

Each successive stage has a (3) Sedimentation.$ The sedimentation method of smaller cutoffdiameter than the previous one, and the particle size analysis is based on the terminal settling particles collected on each stage have diameters be. velocity at which particles fall under gravity through the tween two fixed values. The smallest particle size col- sedimentation medium. The particih diameter deter- lected on the last stage of a typical commercial cascade mined by this method Is termed the Stokes' or sedimen- impactor is well into the submicron range.

tation diameter, and may be defined for irregular parti- cles as the diameter of a sphere having the same settling 3-3.2.2 Correlation of Data From Different velocity under jrav;t?, and the same density as the parti- Methods cle being observed. In some caues, a term called the re- duced sedimentation or equivalent diameter is used for a Definitions found in the literature are presented in sphere of unit density having the same settling velocity Table 3-11 (Ref. 4), In previous studies, particle size in as the particle, the subsieve range has been measured in a variety of Stokes' diameter is calculated from the following re- ways. This variation makes data comparisons between lationship:

data sources difficult and in many cases invalid unless the specific measuring techniques are defined and the CM particle shape factor for that sample is known. For d = 11871Ut/[(P , - Pe)g] , l example, particles classified according to their geomet- (3-9) rical similarity (as in sieving and microscopy) and ac- cording to similarity in hydrodynamic or aerodynamic where behavior (as in sedimentation or elutriation) will in = absolute viscosity of most cases show great variations in equivalent diame- sedimentation medium, poises ters.

Factors of proportionality between particle sizes U, = terminal settling velo.ity of the determined by different methods are defined as shape particle in the sedimentation factors (discussed in par. 3-2.4.2). medium, cms s P, = density of particle, g cm 3-3.2.3 Instrumentation P, = density of sedimentation medium, g cm ' Table 3-12 summarizes the instruments available for g = acceleration due to gravity, 980 sample collection. This table excludes those limited to cm 8-2 laboratory applications and includes the types most The sedimentation medium can be either a gas or a frequently used in sand and dust field studies. liquid. (4) Elutriation.!

In both the sedimentation and the elutriation methods, the size of the particle is calculated 3-4 FACTORS INFLUENCING THE from its rate of fall by the use of Stokes' law. In elutria- SAND AND DUST ENVIRONMENT tion, the dust sample is introduced Into an upward moving stream of liquid or gas of known and adjustable The sand and dust environment is influenced or con- velocity, so that different particle fractions are lifted or trolled by such factors as terrain, wind, temperature, elutriated and the sizes are calculated from the known humidity, and precipitation. None of these factors velocity of the medium.

This technique requires a mini- alone will dictate whether an area has a dust problem mum quantity of several grams of sample to perform or not; rather a critical combination of two or more is particle size clasiflcation. usually required. In the most severe naturally occur- (5) Impaction. Impactors (described in par. 3.3,1) ring situations, such as in desert arnas, all factors gener- can be used for both concentration and particle size ally have values in the range that is highly conducive to heavy dust concentrations. 5. A general refrrencc for this paragraph is Ref. 21. 3-17