US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors (EN)

Downloaded from https://www.everyspec.com AMPC 706-117 means of a mechanical pointer, to transducers that pro- perienced by the mass causes a proportional change in vide a usable electrical output in response to a specific strain within the crystal. This change in strain causes stimulus. The type of transducer most commonly used an electrical potential to be developed across the crystal in shock measurements is electromechanical, i.e., one in proportion to the inertial force or acceleration ex- that converts the energy of mechanical motion into perienced by the mass. The compression spring is pre- electrical energy (Ref. 28).

loaded in such a way that the crystal wafer i* always Although shock excitations and response can be de- maintained in compression. The resulting mechanical scribed in terms of velocity, displacement, or force, the sysLem exhibits a high resonant frequency and virtually vast majority of measurements are made of acceleration no damping. A typical crystal accelerometer is shown as a function of time. The shocks that are encountered in Fig. 5-45. vary from less than 1 0 to several thousand 0 with Crystal accelerometers are available with or without durations of from a few to over 100 ms (Ref. 29). This an electrically isolated case.

Some models are con- wide dynamic range makes it difficult to have a single structed with the seismic mass compressed between measuring system capable of recording all the shock two crystal elements. Accelerometers of improved de- encountered by an item of cargo during intermodal transport, for example. The transducer most often used sign, with the crystal bonded to a button- or mush. becase f is wde dnamc rngeand ighnatral room-shaped mass, avoid the influence of case distor- because of its wide dynamic range and high natural tion.

frequency in the piezoelectric accelerometer, If frequen- Due to the high esonant frequency (on the order of cies above about 400 Hz are of interest, the piezoelec. 30 kHz) of crystal accelerometers, they are well suited tric accelerometer nearly always is used (Ref. 2). for the measurement of both vibration and shock. They can be used to measure shock on the order of 10,000 0 5-7.2 ACCELEROMETERS (peak) and sinusoidal vibration up to 1,000 0 (peak).

Instrumentation for shock measurement usually in- An accelerometer is a transducer whose output cludes low pass filters to avoid falsification of data by quantity varies in proportion to the acceleration that it "ringing" at resonant frequencies. Some progress has experiences. A seismic system consisting of a mass sus- been made in the damping of piezoelectric accelerome- pended from a base by a spring and usually constrained ters. This decreases the ringing and extends the linear to move in only one direction is employed in accelerom- frequency response. The range of linear frequency re- eters as the sensing element (Ref. 2).

In the opersa ing sponse (±5 percent) is on the order of 10 Hz to 10 kHz. frequency range of the transducer, which is below its The operational temperature range of crystal accele- resonant frequency, the mass undergoes nearly the rome.ers is approximately -6r to 50WC. However, same acceleration as the body of the transducer The models that will operate down to - 220"C and measure mass exerts a force on the support that is directly pro- portional to the magnitude of the component of accel- eration, and the output is a known function of the force. The types of accelerometers most generally used for shock measurements are described in the paragraphs PIEZOELECTRIC ELECTRICAL that follow.

OUINT oTPU-r 5-7.2.1 Piezoelectric Accelerometerai Piezoelectric (crystal) accelerometers utilize the abil- ity of certain crystalline materials to generate electrical charge motion when subjected to mechanical stress. MASS These piezoelectric materials contain crystal domains comprising electric dipoles oriented either by natural or artificial polarization. The slight relative motion of these domaina, resulting when a load is applied, causes a charge flow to be generated, The material, under a varying load, functions electrically as a charge-generat- HOUsxIc ing capacitor. One type of crystal accelerometer con- sists ofa seismic mass compressed between a spring and FIGURE 5-45.

Plezomelcc (Crvml) Accelmoeter a wafer of piezoelectric material. The inertial force ex- (Ref. 30). 5.38