Downloaded from https://www.everyspec.com AN"P 706-117 th motion of surfaces at temperatures to +2,200C Unlike crystal accelerometers, the strain bridge type using liquid cooling are available. Instruments de- can be used to measure low acceleration levels at fre- signed for extreme temperature environments are gen- quencies down to zero. The relatively low naturrl fre- erally supplied with calibration curves obtained at vari- quency of strain bridge accelerometers (on the order of ous temperatures. 50n Hz) limits the frequency range of linear response (±5 percent) to approximately 0 to 300 Hz.
5-7.2.2 Strain Bridge Accelerometers These instruments are generally used for measuring The electrical resistance of a wire increases when it accelerations to approximately 2,000 G (peak). Strain is stretched, said decreases when it is compressed axi- bridge accelerometers can be used for low-level shock ally or when an initial tension is relieved. The operation measurement when high frequency information is not of strain bridge accelerometers is based upon this prin- desired. The higher frequencies will be mechanically ciple. One type of bridge accelercmeter consists of a attenuated by the instrument. Strain bridge accelerom- mass suspended by a strain wire spring and a damper.
eters, calibrated over a temperature range of approxi- The inertial force experienced by the mass when it is accelerated induces a change in the strain on the sup- porting wires, aid thus a change in their electrical resistances. Damping of the strain bridge accelerometer 5-7.2.3 Potentiometer Accelerometers varies somewhat with temperature. The a.'celerometer case is generally filled with a viscous fluid that consti- The potentiometer accelerometer consists of a mass- tutes the damping medium. If part of the damping fluid spring-damper system and a potentiometer circuit (Ref. is lost, the decrease in damping can be detected by 31).
The potentiometer wiper is connected to the seis- measuring the frequency response. This response will mi.; mass. A constant voltage is maintained across the be peaked at the resonant frequency when damping is resistance element of the potentiometer. When the in- low. Since the electrical circuit is passive, it must be strument experiences an acceleration, the mass is dis- powered externally. The power supply can be either a placed, causing a proportional change in the output direct current or an alternating current source. To ob- voltage of the potentiometer circuit.
The mass-spring tain adequate sensitivity, the strain wires are arranged system for some models is the form of a cantilever electrically in the form of a Wheatstone bridge. The beam. Viscous fluid is generally used for the damping bridge is balanced externally. The electrical unbalance medium. A potentiometer accelerometer is illustrated of the bridge circuit is then proportional to the acceler- in Fig. 5-47. ation experienced by the instrument. An illustration of To obtain adequate sensitivity, the mass-spring system a strain bridge accelerometer is shown in Fig. 5-46. generally has a natural frequency of approximately 15 Hz, and the system is usually damped from 70 to 140 percent critical.
The low natural frequency limits the STRAIN HOUSING, -7 frequency range of linear response to approximately 0 to E 10 Hz. These instruments are generally used for meas- uring very low accelerations at low frequencies. A typical Instrument might be calibrated for a range + 0.5 SIMC G with a sensitivity of 5 V per G. MHAS S POT ENT"IOMETERl WIPERa OUOUTPUT aHOUSING TR•NALS TERMIINALS EXC ITAT ION SOURCE INPUTE FIGURE 5-46. S/AIn Bridge Acc~eromretr FIGURE 5-47. Potentlcmeter Acculeromer- (Ref. 30). (Ref. 30). 5-39