Downloaded from https://www.everyspec.com AMPC 706.117 TABLE 2-17.
NATIONAL AIR QUALITY STANDARD REFERENCE METHODS Averaging Reference method Principle of Polliutant R e n thdetection s 2 3 hr, 24 hr, Pararosaniline Colorimetric annual Particulate 24 hr, HI-vol sampler Gravimetric matter annual CO 1 hr, 8 hr Nondispersive infrared Infrared spectrometry Photochemical 1 hr Gas phase 0 3 -ethylene Chemiluminescence oxidants reaction (calibrated (ozone) against neutral buffered KI method) Hydrocarbons 3 hr (nonmethane) Gas chromatographic Flame ionization NO 2 Annual 24-hr integrated samples Colorimetric collected in alkaline sol ution In actual sampling situations, to insure a high degree particulates should be determined to the nearest milli- of uniformity in filter exposure, the sampler should.
be gram, air flow rate to the nearest cubic foot per minute, operated in a vertically oriented shelter with the filter and time to the nearest 2 min. in a horizontal position. Shelter design may affect the Although it is not a reference method, the tape sam- collection characteristics of sampling equipment; there- pier method is required for sampling particulates at less fore, care should be exercised when comparing data than 24-hr intervals (e.g., one sample every 2 hr), as from samples collected at sites where different types of would be necessary under emergency episode condi- shelters have been used.
larger than the filter area, around the circumference of the high-volume sample has been found not to be uni- The standard shelter provides an air opening, slightly tions. The correlation of the tape-sampler method with the sampler. This opening Is oriented so that the Intake form in all areas of the United States: however, this airflow Is vertically upward. Therefore, with an average method is the only one available for short-term moni- velocity of 64 fts min" across the horizontal air Inlet toring of particulates. Fig. 2-30 is the schematic dia- portal of the shelter, the collection of particles Is gener- gram of a typical tape sampler. ally limited to those 100 jrm or less In diameter.
Particles Air is drawn through a I-in.-diameter spot (white too large to remain aIrborne are excluded and variations filter paper) at a flow rate of 7.0 liters/min (0.25 ft' caused by shifting winds are minimized. Fip. 2-28 and min ')for periods up to 4 hr. At the end of the sam- 2-29 give an exploded view and an assembled view, piing period, the tape advances automatically by means respectively, of a high-volvme sampler and standard of a timing mechanism, placing a clean section of filter shelter, paper at the sampling port.
The collected spot is posi- Concentrations of suspended particulates as low as I tioned under a photoelectric transmittance head that э.g m-1 can be obtained when the sampler is operated measures the optical density of the spot. The greater the at an average flow rate of approximately 40 ft 3 amount of particulate matter filtered out of the air, the min- 'based on a sampling period of 24 hr. Weight of darker the spot. The quantity of air sampled is ex- 2-44