Hantek — :TRIGger:TIMeout:SLOPe

For example, :TRIGger: VIDeo: LEVel 0.16 /*Set the trigger level to 160mV*/ :TRIGger: VIDeo: LEVel? /*The query returns 1.600000e-01*/ :TRIGger: TIMeout :TRIGger:TIMeout:SOURce For example, :TRIGger:TIMeout: SOURce CHANnel2 /*Set trigger source to CH2*/ :TRIGger:TIMeout: SOURce? /*The query returns CHAN2*/ :TRIGger:TIMeout:SLOPe For example, :TRIGger:TIMeout:SLOPe NEGative /*Set edge type to falling edge*/ :TRIGger:TIMeout:SLOPe? /*The query returns NEG*/ 76 / 136 Integer (-5 × VerticalScale - OFFSet)至 (5 × VerticalScale - OFFSet) 0 Description This setting command is valid only when the selected source is an analog channel.

Return format The query returns the trigger level in scientific notation. Command format :TRIGger:TIMeout:SOURce :TRIGger:TIMeout:SOURce? Function description Sets or queries the trigger source of the timeout trigger. Parameter Name Type Range Default Discrete {D10|D11|D12|D13|D20|D21|D22| D23|D30| D31|D32|D33|D40|D41|D42|D43| CHANnel1|CHANnel2|CHANnel3| CHANnel4} CHANnel1 Description When the digital channel is used as the trigger source channel, the digital probe must be connected to the oscilloscope. Return format The query returns D10, D11, D12, D13, D20, D21, D22, D23, D30, D31, D32, D33, D40, D41, D42, D43, CHAN1, CHAN2, CHAN3, CHAN4.

Command format :TRIGger:TIMeout:SLOPe :TRIGger:TIMeout:SLOPe? Function description Sets or queries the type of edge triggered by the timeout. Parameter Name Type Range Default Discrete {POSitive|NEGative|RFALl} POSitive Description POSitive: Start the timing by the trigger level on the rising edge of the input signal. NEGative: Starts timing with the trigger level on the falling edge of the input signal. RFALl: Start timing by trigger level at any edge of the input signal. Return format The query returns POS, NEG, or RFAL.