Delta DVP-ES3 — 6.18.2 Explanation of Peripheral Instructions

DVP-ES3 Series Programming Manual 6. When using on-line editing, please reset the conditional contact to initialize the instruction. Example 1. X0–X3 are connected to Y0–Y3 to form the first DIP switch, and X4–X7 are connected to Y0–Y3 to form the second DIP switch. When M10 is ON, the instruction converts the value that you enter with the first DIP switch into the binary value, and stores the conversion result in D20. The instruction converts the value that you enter with the second DIP switch into the binary value, and stores the conversion result in D21. 2. When M10 is ON, Y0–Y3 are ON cyclically. After the instruction completes, SM694 is ON for a scan cycle. 3.

The following graphic shows the outputs. Y0–Y3 must be transistors. M10 Cyc lic action _6 Y0 0.1s 0.1s 0.1s Y2 0.1s Interruption Y3 0.1s SM694 I nstruct ion execution is complete. 6-516 Y1