Delta DVS — 3.1.9.1 Global Configuration

Chapter 3 Featured Functions 3.1.8.5 Console Port You can configure console port configuration in this page. Console Port 3.1.9 Loopback-Detection The Loopback-Detection has two configurations: Global Configuration and Port Configuration. 3.1.9.1 Global Configuration The Module Status of Loopback-Detection Global Configuration is used to Enable/Disable the Loopback-Detection feature. 3-33 Description Factory Default Maximum Number of Telnet Sessions The maximum number of inbound Telnet sessions that are allowed on the switch. The number must be in the range of 0 to 5. 5 Current Number of Telnet Sessions This field displays the number of simultaneous Telnet sessions.

0 Description Factory Default Console Login Timeout (minutes) The console port session time-out period in minutes. When there is no activity and the time-out period is reached, the console port session is closed. The period must be in the range of 0 to 160 minutes. Entering 0 disables the time-out. 30 Description Factory Default Module Status Specify whether the status in the global configuration is activated or not. Enable