6 - 2 Monitor Screen This monitor screen allows you to display and change the status of sensor amplifiers that are connected to the E3NW-ECT Communication Unit. Up to 6 sensor amplifiers can be displayed per page. (2) (7) (8) (6) (5) (4) (3) (9) (9) (1) (10) 22 No. Function Description (1) Sensor information Displays and controls information for each sensor amplifier. For the details, see the next page. (2) Node address Indicates a node address of the displayed slave. (3) Number of the sensors Displays No. of the connected sensors and the status. (4) Button for all selection (Select all, Clear all) Selects and clears all sensor amplifiers targeted for all settings (tuning, detail setting).
(5) “Menu” button Moves to the Menu screen. (6) “Select a workpiece” button Moves to the Select workpiece screen. (7) “Tuning all” button Moves to the Select all tuning function. (8) "All Detailed Settings" button Moves to Setting all Detailed Settings Screen. (9) button Moves forward or backward one page. (if the first page is showing, the last page will be displayed by pressing this button, and if the last page is showing, the first page will be displayed) (10) Button for individual selection (individual select, individual clear) Selects and clears individual sensor amplifier targeted for all settings (tuning, detail setting).