E774GB — 1 Modification History

Introduction 1 Modification History 6 E 774 GB 30.06.2014 Version Date Subject E774D 31/08/2010 Initial release based on the tailored power heat controller model E774D 09/12/2010 Addenda to the installation and change of fuse sections Details about the PROFIBUS fieldbus interface E774D 12/05/2011 New / changed functions at migration from software release SW 2.01 to SW 2.02 or SW 1.04 of hardware HW 1.0x 7.5.1 Channel Error at Pilot Stage 7.5.3 Error Suppression at Soft Start 8.1 Module State (ModuleWarning freewheeling) E774D 01/06/2011 Status indicators 7.5.3 Error Suppression at Soft Start E774D 01/08/2011 Use of inhibit signal at start-up in units running software 2.03 7.5.3 Error Suppression at Soft Start E774D 01/08/2011 7.6.2 Power Mains Disturbances E774D 01/08/2011 0 Half sine wave control is intended to separately control each of multiple continuously operated IR lamps.

After the soft start stage, the thermo- controller automatically sets itself to the specified heat output. As opposed to phase-fired control, half sine wave control is based on com- plete half-cycles. Interconnecting 3 output channels allows complete sine waves to be picked off the mains, thereby substantially reducing harmonic perturbations of the electrical power mains. Load power variation between 0...100% in steps of 1%. Mains Voltage Correction E774D 01/08/2011 8.8 Module Control Information about actively selecting error suppression using the inhibit signal, cf.

7.5.3 Error Suppression at Soft Start E774D 01/11/2011 Legibility improved by clearing up the layout and removing errors E774D 01/11/2011 7.4 Power Output Fuses Fuse type changed from 16A to 20A E774D 13/12/2011 7.4 Power Output Fuses Fuse type changed from 16A to 20A E774D 13/12/2011 Legal notice added to document: EtherCAT® is a registered trademark and patented technology, licenced by Beckhoff Automation GmbH, Germany. E774D 15/06/2012 5.3 Auxiliary Supply "24VDC", X10 Advanced Instructions for the auxiliary supply in UL applications or machine.

E774D 10/09/2012 6.7 Output Branch Circuit protection according UL 508A Call to action for use in UL member territories E774D 13/12/2011 7.4 Power Output Fuses Fuse type changed for UL marked units from 20 A to 16 A E774D 17/01.2013 6.5 Power Supply Definition of the power supply and power form for USA E774D 17/01/2013 8.9 Notes on parameter "Voltage Tolerance" E774D 05.03.2013 6.7.3 Requirements for the output lines Guidance on minimum requirements. E774 18.04.2013 5.7 Output Channel Terminals, X1 … X6 7.4.3 Allocation of Fuses and Output Channels