Kendrion Kuhnke Automation GmbH Hardware 4.2 Ports 4.2.1 General information The spring-assisted PUSH-IN connector allows you to quickly attach the wires by direct insertion without any tools. Just insert the connector sleeve end of the stripped solid or fine wire in the correct opening. Wires: 320V / 13.4 A / 0.14 - 1.5 mmІ (IEC) Nominal current: 300 V / 9.5 A / 26 - 16 AWG (UL) Supported wires with connector sleeves: 4.2.2 I/O connector Both the system power supply and the I/Os connect to the same 36-pole module terminal block. Figure 7:
Two-row push-In connector with releasing lever Kuhnke FIO CAM Control ( E 808 GB ) 17 11/10/2017 Wire cross section [mm2] Connector sleeve type 0.14 0.25 0.34 0.50 0.75 1 1.5 Connector sleeve w/ collar to 8 / 10 8 / 10 8 / 10 10 / 12 12 / 14 12 / 15 DIN 46 228/4 Connector sleeve w/o collar to 10 / 10 DIN 46 228/1 Stripped end [mm] / sleeve length [mm] NOTE Do not connect the power supply lines through from one Kuhnke FIO to the next. To ensure that there is as little interference as possible, install a central power supply point and establish a star topology of as short wires as possible between the central point and Kuhnke FIO.