Technical Manual for EA350 Analog Pulse Type Servo Driver V101 Parameter functions: Set the delay time for activation and inactivation of each VDI. These functions are intended for VDI input. Please refer to P6-86~P6-97. Caution ☞ 1: P6-75~P6-82 are intended for virtual terminal VDI instead of actual DI intput terminal. 2: Please use this function with caution, especially for invalid delay of DI, otherwise unexpected results might occur due to command delay.

189 P6-80 VDI3 invalid delay Initial value 0 Communication address 0650H Unit ms Time of taking effect With immediate effect Setting range 0~65535 Data size 16bit Control mode P S T P6-81 VDI4 valid delay Initial value 0 Communication address 0651H Unit ms Time of taking effect With immediate effect Setting range 0~65535 Data size 16bit Control mode P S T P6-82 VDI4 invalid delay Initial value 0 Communication address 0652H Unit ms Time of taking effect With immediate effect Setting range 0~65535 Data size 16bit Control mode P S T P6-83 VDI level logic Initial value 00000000B Communication address 0653H Unit - Time of taking effect With immediate effect Setting range 00000000B~11111111B* Data size 16bit Control mode P S T