E23 Defective triac for drain pump OFF/reset E24 Malfunction in sensing circuit on triac for drain pump OFF/reset E31 Malfunction in pressure switch circuit (frequency of signal from pressure switch out of limits) OFF/reset OFF/reset OFF/reset QUICK GUIDE AND APPLIANCES LIST Alarm Description Reset E00 --- Start Start E13 Water leaks Start Start Start Start EWM1000plus EWM2000evo EWM3000new E12 Difficulty in water fill during drying (maximum time 3 min.

water fill in drying during the wash load unrolling phase) Electronic pressure switch improperly calibrated (level on electronic pressure switch differs from 0-66 mm after initial calibration drain and when antiboiling pressure switch is on “empty”). Inconsistency between level on electronic pressure switch and level on antiboiling pressure switch 1-2 (fault persists for at least 60 sec.). Inconsistency between level on electronic pressure switch and level on antiboiling pressure switch 2 (fault persists for at least 60 sec.).

E22 Difficulty in water fill during drying or drying condenser clogged (anti-boiling pressure switch closed on “FULL”) E11 Poor water fill before wash cycle E21 Poor draining E32 E33 E34 Alarm Description Possible malfunction Action/status of machine Reset E00 No alarm --- E11 Poor water fill before wash cycle Tap closed or water pressure too low; Drain tube improperly positioned; Water fill solenoid valve is defective; Leaks from water circuit on pressure switch; Pressure switch defective; Wiring defective; Main board defective. Cycle is paused with door locked Start E12 Difficulty in water fill during drying (maximum time 3 min.

water fill in drying during the wash load unrolling phase) Tap closed or water pressure too low; solenoid valve; pressure switch water circuit; pressure switches; wiring; main board. Cycle is paused Start E13 Water leaks Drain tube improperly positioned; Water pressure too low; Water fill solenoid valve is defective; Water circuit on pressure switch is leaking/clogged; Pressure switch defective. Cycle is paused with door locked Start E21 Poor draining Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump defective; Pressure switch defective; Wiring defective; Main board defective; Electrical current leak between heating element and ground.

Cycle is paused Start E22 Difficulty in water fill during drying or drying condenser clogged (anti-boiling pressure switch closed on “FULL”) Drain hose kinked; filter clogged: drying condenser clogged; drain pump faulty; pressure switches faulty; wiring; main circuit board defective; current leakage between heater and ground. Cycle is paused Start E23 Defective triac for drain pump Drain pump defective; Wiring defective; Main board defective. Emergency drain procedure - Cycle stops with door unlocked OFF/reset E24 Malfunction in sensing circuit on triac for drain pump Main board defective.

Emergency drain procedure - Cycle stops with door unlocked OFF/reset E31 Malfunction in pressure switch circuit (frequency of signal from pressure switch out of limits) Pressure switch; Wiring; Main board; Cycle stops with door locked OFF/reset E32 Electronic pressure switch improperly calibrated (level on electronic pressure switch differs from 0-66 mm after initial calibration drain and when antiboiling pressure switch is on “empty”).

Tap is closed or water pressure is too low; Solenoid valve; Water circuit on pressure switches; pressure switches; Wiring; main board; Cycle is paused Start E33 Inconsistency between level on electronic pressure switch and level on antiboiling pressure switch 1-2 (fault persists for at least 60 sec.). Pressure switch defective; Electrical current leak between heating element and ground; Heating element; Wiring defective; Main board defective. Water circuit; Emergency drain procedure - Cycle stops with door unlocked OFF/reset E34 Inconsistency between level on electronic pressure switch and level on antiboiling pressure switch 2 (fault persists for at least 60 sec.).

Pressure switch defective; Electrical current leak between heating element and ground; Heating element; Wiring defective; Main board defective. Water circuit; Emergency drain procedure - Cycle stops with door unlocked OFF/reset