electrolux EWM21xx EWM25xx — Electrolux EWM21xx EWM25xx Washing Machines & Washer-Dryers Service Manual (EN)

11.1 Temperature control The drying temperature is controlled by an NTC sensor positioned on the duct. The heater casing features two safety thermostats (one of which is a manual-reset type). 1. Circuit board 2. Anti-boiling pressure switch AE1 3. Safety thermostat (auto-reset) 4. Drying heater 5. Safety thermostat (manual reset) 6. Anti-boiling pressure switch AE2 7. Fan motor 8. Drying control sensor (NTC) 9. Humidity control sensor (NTC) Calculating the drying time: In automatic cycles, the NTC sensor fitted to the drying duct is used to calculate the drying tim . 1. NTC temperature sensor 2. Tube from tub to condenser 3. Drying condenser SOI/DT 2007-11 dmm 52/69 599 70 39-88 1.

Drying temperature control thermostat (NTC) 2. Safety thermostat (auto reset) 3. Manual-reset safety thermostat (150°C) 4. Drying heater NTC sensor: resistance at 25°C 5000Ω Manual-reset safety thermostat Normally closed Opens at 150°±5°C Auto-reset safety thermostat Normally closed Opens at 110°±3°C Closes at 94°±5° Heater group Power 920+920 W Voltage 230V 240V Resistance 56,5Ω+56,5Ω 61,5Ω+61,5Ω Fan capacity 80 m3 – hour