electrolux EWM1100 — Electrolux EWM1100 — руководство по ремонту (EN)

5.2 Reading the alarm codes It is possible to display the last three memorised alarms in the FLASH memory of the electronic board: Enter diagnostic mode (par. 4.1). Irrespective of the type of PCB and configuration, turn the programme selector clockwise to the tenth position . The last alarm is displayed. To display the previous alarms, press sequentially the left button of the START/PAUSE button (as represented in figure). To return to the last alarm, press the START/PAUSE button. 5.2.1 Alarm displaying AEG Version:

The alarm is displayed by a repeated flashing sequence of the START / PAUSE button with yellow and red light (0,5 seconds on, 0,5 seconds off with a 2,5 second pause between the sequences). button indicator START / PAUSE with yellow light indicates the first digit of the alarm code (family) button indicator START / PAUSE with red light indicates the second digit of the alarm code (internal number of the family) These two LEDs are featured in all models. Other versions: The alarm is displayed by a repeated flashing sequence of the START / PAUSE button with red and green light (0,5 seconds on, 0,5 seconds off with a 2,5 second pause between the sequences).

LED indicator START / PAUSE with red light indicates the first digit of the alarm code (family) LED indicator START / PAUSE with green light indicates the second digit of the alarm code (internal number of the family) These two LEDs are featured in all models . 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 11/59 599 70 32-47